DATA LOGGER MX-9
MX-9 is Wireless M-Bus Data logger / Gateway (433/868 MHz OMS)
The MX-9 data logger allows reading of Wireless M-Bus, Modbus and M-Bus devices, and send the data to remote users / server through Modbus GPRS modem or Ethernet. It also provides SMS sending services for alarm events. Data logger can read Kamstrup, Sensus, DIEHL, Danfoss, Itron, Landis & Gyr and other meters (like exotic meters / industrial meters).
Application possibilities
Data Logger MX-9 is dedicated for reading Wireless M-Bus meters, real time logging and analyzing of data. Using GPRS/GSM or Ethernet, logger sends data to remote users / server. MX-9 can also communicate with other controllers and sensors. Device has wide range of optional interfaces and protocols and can read any kind of meters, controllers and sensors equipped with standard protocols. Perfect for smart metering of commercial, residential or industrial buildings.
Water metering
Environmental monitoring
Electricity metering
Renewable energy monitoring
Gas metering
Industrial metering and control
Heat substation metering
Wireless M-Bus metering
Smart house
Commercial metering
Device adjustment to client’s needs
If client needs custom made application or special functions, our R&D department ready to help. We can adjust our devices, include special protocols or interfaces to meet client application’s needs. Also we are ready to adjust our device for working with various meters, flow meters (even exotic ones). If you are not sure if our device can satisfy your needs, feel free to contact us anytime.
MX-9 can read: Kamstrup, Sensus, Danfoss, L+G, Itron, Diehl, Apataor and other manufacturer’s meters. Also MX-9 can read and controll other controllers, like Danfoss ECL 300.
Application examples
Below indicated few samples how MX-9 collects the data from Wireless M-Bus meters / sensors and controllers and sends the data to local or remote users using Modbus protocol via GPRS / GSM or Ethernet. There is so many ways to use our MX-9. Starting from smart metering (from WIreless M-Bus meters), heating substation metering, data acquisition from temperature, pressure sensors, data acquisition from weather stations and sensors, chemical monitoring and telemetry, to smart house telemetry, and scientific device monitoring and telemetry.
– Possibility to choose interfaces: Wireless M-Bus (433 / 868 MHz), M-Bus, RS232, RS485, Current Loop, Data/Req, USB, GSM/GPRS, Ethernet
– Reading data from any kind of meters (water, electricity, heat, gas, cooling …) and controllers.
– Supported protocols: Wireless M-Bus, Modbus RTU, Modbus TCP/IP, M-Bus, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, SNTP, IEC60870-5-104:200 and transparent.
– Independent data log with real time stamp (Real Time Clock).
– Wireless M-Bus modes supported: T1, T2, S, S1, R,C,C1,N.
– Remote communication and updates through GSM/GPRS or Ethernet
– Galvanically isolated interfaces and power supply
– SMS sending for alarm events.
– Additional special transparent protocol data transfer.
– Power supply for external powering of meters
– Memory expansion: up to 32 GB using micro SD card
Did you know?
– MX-9 can read Kamstrup, Sensus, Diehl, Apator and other meters.
– MX-9 can read variuos exotic Wireless M-Bus meters.
– MX-9 can read Enless Wireless sensors and Fast Forward AG Energy Cam.
Description | Data Logger MX-9 technical specifications |
---|---|
CPU | ARM7 |
Flash | archive storage up to 8 MB, independent data storage without power about 5 years |
External memory | up to 8 GB micro SD card |
RS232 (4 ports) | distance up to 15 m, speed up to 19,2 Kbit/s |
RS485 (3 ports) | distance up to 1,2 km, max 32 transivers, speed up to 19,2 Kbits/s |
M-Bus (2 ports) | up to 16 M-Bus devices (up to 8 M-Bus devices for each M-bus port) |
Wireless M-Bus (1 port) | up to 300 M-Bus devices |
Data/Req (2 ports) | (KAMSTRUP) data transfer interface |
Current Loop (2 ports) | <30V, 14-20mA, up to 6 km, speed up to 19,2 Kbit/s |
GSM/GPRS | 4 band 850/900/1800/1900 MHz |
Ethernet | 10/100 Mbps, RJ45, distance up to 100 m |
USB | ver. 2,0, type A |
Protocols | Modbus RTU, Modbus TCP/IP, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, SNTP, IEC60870-5-104:2000, DynDNS, FTP server, FTP client, DNS client |
Power supply | 9-36 VDC |
Over-voltage protection | >1000V |
Power consumption | <10VA |
Power for external devices | 3,7/5/6/8/10 V (<20mA) |
Interface galvanic isolation | 500V |
Dimensions | 147x128x50 mm |
Weight | 450 g |
Mounting type | on DIN rail |
Protection type | IP20 |
Operating temperature | -25 to +60oC |
Real time clock | Yes |
M-Bus auto setup | Yes |
Warranty period | 2 years |