20W Single Output Industrial DIN Rail Power Supply

Original price was: €35.00.Current price is: €28.00.

More info

ORDERING CODE:
• Power supply (5V)
• Power supply (12V)
• Power supply (15V)
• Power supply (24V)

Additional information
DC VOLTAGE

5V

,

12V

,

15V

,

24V

Technical features

Features:
• Universal AC input/Full range;
• Protections: Short circuit / Overload /
Over voltage;
• Cooling by free air convection;
• Can be installed on DIN rail TS-35/7.5
or 15;
• Built in DC OK active signal;
• LED indicator for power on;
• No load power consumption <0.75W;
• 100% full load burn-in test;
• 2-year warranty.

Technical specifications
OUTPUT DC VOLTAGE  5V  12V  15V  24V
RATED CURRENT  3A  1.67A  1.34A  1A
CURRENT RANGE  0 ~ 3A  0 ~ 1.67A  0 ~ 1.34A  0 ~ 1A
RATED POWER  15W  20W  20W  24W
RIPPLE & NOISE (max) 80mVp-p  120mVp-p  120mVp-p  150mVp-p
VOLTAGE ADJ. RANGE  4.75 ~ 5.5V  10.8 ~ 13.2V  13.5 ~ 16.5V  21.6 ~ 26.4V
VOLTAGE TOLERANCE ±2.0%  ±1.0%  ±1.0%  ±1.0%
LINE REGULATION  ±1.0%  ±1.0%  ±1.0%  ±1.0%
LOAD REGULATION  ±1.0%  ±1.0%  ±1.0%  ±1.0%
SETUP, RISETIME 500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load.
HOLD UP TIME  50ms/230VAC 20ms/115VAC at full load.
INPUT VOLTAGE RANGE  85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE  47 ~ 63Hz
EFFICIENCY (Typ.)  76%  80%  81%  84%
AC CURRENT (Typ.)  0.55A/115VAC 0.35A/230VAC
INRUSH CURRENT  

(Typ.) 

COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT  <1mA / 240VAC
PROTECTION OVERLOAD 105 ~ 160% rated output power
Protection type: Constant current limiting, recovers automatically  after fault condition is removed.
OVER VOLTAGE  5.75 ~ 6.75V  13.8 ~ 16.2V  17.25 ~ 20.25V  27.6 ~ 32.4V
Protection type: Shut down o/p voltage, re-power on to recover.
FUNCTION  DC OK ACTIVE SIGNAL  (max.) 3.75 ~ 6V /  

50mA

9 ~ 13.5V /  

40mA

11.5 ~ 16.5V /  40mA 18 ~ 27V /  

20mA

ENVIRONMENT WORKING TEMP.  -20 ~ +70(Refer to “Derating Curve”).
WORKING HUMIDITY  20 ~ 90% RH non-condensing.
STORAGE TEMP.,  

HUMIDITY 

-40 ~ +85, 10 ~ 95% RH
TEMP. COEFFICIENT  ±0.03%/(0 ~ 50)
VIBRATION Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z  axes;  

Mounting: Compliance to IEC60068-2-6

SAFETY & 

EMC

SAFETY STANDARDS  UL508, TUV EN60950-1 approved.
WITHSTAND VOLTAGE  I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE  I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSION  Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B,  EN61000-3-2,-3
EMC IMMUNITY  Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6- 1,EN61204-3, light industry level, criteria A
OTHERS MTBF  236.9K hrs min. MIL-HDBK-217F (25)
DIMENSION  22.5*90*100mm (W*H*D)
PACKING  0.17Kg; 72pcs/13.2Kg/0.91CUFT
NOTE 1. All parameters NOT specially mentioned are measures at 230VAC input, rated load and  25oC of ambient temperature. 

2. Ripple & noise are measured at 20MHz of bandwidth by using 12“ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 

3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final  equipment. The final equipment must be re-confirmed that it still meets EMC  directives.  

5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply  may lead to increase of the set-up time.